Commercial Security Intercom
AI-900 Components
AI-MS900
SCHOOL, INSTITUTIONAL, PARKING, BUILDING
SCHOOL, INSTITUTIONAL, PARKING, BUILDING
AI-900MS Master Station
The AI-900MS can initiate or receive calls from
programmed substations. Equipped with Push-
to-Talk button for simplex communication, vox
operated handset, redial and transfer keys, and
eight auto-dial keys. Alphanumeric display for
caller ID. Two-twisted pair wiring to Main Frame.
The AI-RS150 is built with a black resin call
button and 14-gauge stainless steel. It can call
and converse with the programmed master
stations. All substation models are wired with a
shielded pair to the Main Frame.
AI-RS150 Standard Indoor Substation
The AI-RS160 is made with heavy 11-gauge
stainless steel and a vandal resistant stainless
steel call button. Calls and communicates with
programmed master stations or telephones.
AI-RS160 Indoor Vandal Resistant Substation
The AI-RS170 is equipped like the AI-RS160,
but with the internal components protected with
a synthetic rubber sealant, making it weather
resistant. Calls and communicates with
programmed master stations or telephones.
AI-RS170 Outdoor Vandal Resistant Substation
The AI-RS180 is vandal and weather resistant
with a red aluminum call button, call assurance
LED, and an output to control an external relay.
Used for ADA compliance or emergency call
applications.
AI-RS180 Outdoor Emergency Substation
The SBX-2G is used for surface mounting the RS substations where flush
mounting these substations is not possible.
SBX-2G Surface Mount 2-Gang Stainless Steel Enclosure
216
74.5
213
2
48.5
120
120
3
120 57.5
120
3
120 57.5
120
3
58.5120
120
AI-RS150
AI-RS160
AI-RS170
AI-RS180
AI-900MF
AI-PU200
AI-PN100B
AI-YC303
Interface Cards
AI-900MS Master Station Interface Card
One or two cards per Main Frame. The AI-900MS card provides connection
and audio recording outputs for one or two master stations. With two cards
installed, four master stations can be connected to one Main Frame.
AI-900AL Telephone Master Station Card
One or two cards per Main Frame, used in lieu of AI-900MS card. The AI-
900AL allows a standard telephone with caller-ID capabilities to be used in
place of a master station for communication functions. One or two phones per
card, taking the place of an AI-900MS card supporting two master stations.
Equipped with audio recording outputs for each telephone connected.
AI-900RS, Substation Interface Card
Up to four cards per Main Frame. Each AI-900RS card supports up to 16
substations, and up to 64 substations per Main Frame with four cards installed.
Connect subs with simple two conductor shielded wire homerun to the Main
Frame.
AI-900CO C/O Telephone Line Interface Card
One card per Main Frame. The AI-900CO allows the connection of up to two
outside phone lines, with audio recording outputs for each line. integration with
outside lines allows communication between sub or master stations and
standard telephones, cell phones, or pagers.
AI-900AF Audio Function Card
Connection of external PA amplifier for paging. Up to four inputs from audio
sources and 16 outputs to external paging zones. Multiple zones or all zones
can be selected and paged simultaneously.
AI-900TI Tie Line Interface Card
One card per Main Frame in multi-exchange system. The AI-900TI card is used
to interconnect multiple Main Frames, expanding the capacity and functionality
of the system. Up to four voice paths between Main Frames.
AI-900DI Direct-Select/Master Station Interface Board
Used to create a direct-select style master station in place of a digital master.
Used with AI-910DI for individual selector buttons and call-in LEDs. Also allows
integration with external security systems via AI-910DI board.
AI-910DI Direct-Select Input/Output Relay Board
The AI-910DI is used in conjunction with the AI-900DI board to provide relay
outputs to control external devices or systems. Each board contains 32
programmable relays, and multiple boards can be used for up to 1024 relays.
Use for integration with access control and/or video surveillance systems.
Specifications (AI-900)
Power Source
Current Consumption
Communication Modes
Serial Ports
Operating Temperature:
- Indoor Units
- Outdoor Units
System Capacity
Master Station Mounting
Master Station Wiring
Substation Mounting
Substation Wiring
Wiring Distance:
- Master to AI-900MS
- Subs to AI-900RS
- Between Main Frames
Dimensions:
- AI-900MF
- AI-900MS
- AI-RS150/160/170/180
20V AC, 2.5A, provided by AI-PU200; 24V DC provided
by external 5A power supply not supplied Aiphone
7A
Duplex, half-duplex, and Push-to-Talk
RS-232 compliant, D-sub connector (9-pin female) 2 ports
0°C-40°C
-10°C-55°C
4 master stations; 64 substations per Main Frame
Wall or desk mount
2 twisted pairs, homerun to Main Frame
Flush mount in 2-gang box
2 conductor shielded, homerun to Main Frame
900m w/0.5mm; 1,500m w/0.65mm
500m w/0.5mm; 800m w/0.65mm
600m w/0.5mm; 1,000m w/0.65mm
(WxHxD)
420 x 443.7 x 288.3
216 x 74.5 x 213
120 x 120 x 60
The AI-900MF Main Frame can accommodate
the following features with the installation of the
corresponding circuit cards. Up to 4 master
stations or single line phones (2 masters per
AI-900MS card; 2 phones per AI-900AL card);
up to 64 substations; up to 2 CO lines; paging to
19 zones; tie line connection to additional Main
Frame, RS-232 input/output for system
programming and event logging.
AI-900MF Main Frame
The AI-PU200 has two 20V, 2.5A AC outputs.
One unit is required for every two AI-900RS
cards installed in the Main Frame.
AI-PU200 Power Transformer Unit
The AI-PN100B is used to rack mount two
AI-PU200 power transformers side-by-side.
AI-PN100B Rack Mount Panel
The AI-YC303 is used to wall mount the
AI-900MF Main Frame.
AI-YC303 Main Frame Wall Mounting Bracket
420
483.6
288.3
443.7
178
160
120
220V 240V
20V 2.5A
TO EX-200
OUTPUT
250V 71A
20V 2.5A
TO FC-210